Acrel AKH-0.66 / M8 Current Transformer

Acrel AKH-0.66/M8 Series Current Transformer small primary current, capacity 2.5VA and below for measurement or protection, mostly used in low-voltage cabinets and other small space places.

Double M8 current transformer is made of flame retardant and high temperature resistant material by injection molding, the iron core is made of oriented cold rolled silicon steel tape, and the secondary lead is made of high strength electromagnetic enameled wire.

  • 5-100A measure

  • Application for protect

  • Suitable for small space

  • 0.66KV low-voltage system

Parameters of AKH-0.66/M8 Series Current Transformer


Spec. and sizeAKH-0.66/M8 Series Current Transformer
TypeOutline sizeThrough sizeMounting sizeTolerance
(mm)
WHDΦaeMN
M8678630///70.880.5±1
Double M8678656///70.880.5


ShapeSpecificationRated current ratio (A)Precision degree and corresponding rated load(VA)Straight- through tumsInstallation
0.2S0.5S0.20.51
AKH-0.66/M8 Series Current Transformer M8M85-100/5(1)



2.5DirectH
Double M85-100/51.51.51.5


Video of Measurement Current Transformer

Diagram of AKH-0.66/M8 Series Current Transformer


AKH-0.66/M8 Series Current Transformer is installed in H-Type: Fixed by fixed plate. Note: when the current transformer is in use, the secondary open circuit shall not be allowed, and the secondary outlet S2 shall be grounded!


Diagram of AKH-0.66/M8 Series Current Transformer

Benefits of AKH-0.66/M8 Series Current Transformer


  • Small size and light mass

  • Large capacity

  • High accurancy with CE standard

  • Suitable for low voltage drawer cabinet


Use of AKH-0.66/M8 Series Current Transformer


  • Used for internal measurement in industrial and mining enterprises

  • Measure 5-100A primary current in the power distribution room

  • Convert the large current at the primary side to 5A or 1A, connect to energy meter

  • When using a current transformer, the secondary open circuit is not allowed, and the secondary outlet S2 should be grounded