Acrel AKH-0.66/III Series Current Transformer Clamshell design, beautiful appearance, convenient wiring. Cover material selection with transparent polycarbonate, you can clearly see the secondary lead connection.

Vertical side Pass type, can pass through 1-3 busbar, not only has the characteristics of type I, II, And can be used for power supply system metering, and can be matched with current relay Used for protection.

  • Clamshell design

  • Beautiful shape easy wiring

  • High accurancy

  • Suitable for busbar

Parameters of AKH-0.66/III Series Current Transformer


Spec. and sizeAKH-0.66/III Series Current Transformer
TypeOutline sizeThrough sizeMounting sizeTolerance
(mm)
WHDΦaeMN
60III11714755/5262//±1
80III11716755/5282//
100III12019055/52102//
130III12522455/52132//


Cross-reference tables of spec. –parameter






ShapeSpecificationRated current ratio (A)Precision degree and corresponding rated load(VA)Straight-through tumsBus spec(mm)/numberInstallation
0.20.5
AKH-0.66/III Series Current Transformer 60III60III200-300/5(1)
2.5
60×10/1-3E
400/5(1)
51
500-800/5(1)
101
1000/5(1)10
1
1200-1500/5(1)15
1
2000/5(1)20
1
2500/5(1)30
1
AKH-0.66/III Series Current Transformer 80III80III300-400/5(1)
5180×10/1-3
500-800/5(1)
101
1000/5(1)10
1
1200-1500/5(1)15
1
2000/5(1)20
1
2500-3000/5(1)30
1
AKH-0.66/III Series Current Transformer 100III100III600-800/5(1)
101100×10/1─3
1000/5(1)10
1
1200-1500/5(1)15
1
2000/5(1)20
1
2500-5000/5(1)30
1
130III2000/5(1)20
1130×10/1-3
125×10/1-3
2500-6300/5(1)30
1


Video of Current Transformer Measurement Circuit

Diagram of AKH-0.66/III Series Current Transformer


AKH-0.66/III Series Current Transformer is installed in E-Type: Fixed by generatrix. Note that when the current transformer is in use, the secondary open circuit shall not be allowed, and the secondary outlet S2 shall be grounded.Rated operation voltage AC 0.66kV and Rated frequency 50-60Hz.Used in place without direct rain and snow,without severe pollution and acute shock.


Diagram of AKH-0.66/III Series Current Transformer

Benefits of AKH-0.66/III Series Current Transformer


  • Clamshell design easy to view wiring

  • Beautiful shape easy wiring

  • high accurancy with CE standard

  • suitable for busbar


Use of AKH-0.66/III Series Current Transformer


  • Used for internal measurement in industrial and mining enterprises

  • Measure 1-3 busbar in the power distribution room

  • Convert the large current at the primary side to 5A or 1A, connect to energy meter

  • When using a current transformer, the secondary open circuit is not allowed, and the secondary outlet S2 should be grounded