Acrel AKH-0.66/III Series Current Transformer Clamshell design, beautiful appearance, convenient wiring. Cover material selection with transparent polycarbonate, you can clearly see the secondary lead connection.
Vertical side Pass type, can pass through 1-3 busbar, not only has the characteristics of type I, II, And can be used for power supply system metering, and can be matched with current relay Used for protection.
Clamshell design
Beautiful shape easy wiring
High accurancy
Suitable for busbar
Spec. and size | |||||||||
Type | Outline size | Through size | Mounting size | Tolerance (mm) | |||||
W | H | D | Φ | a | e | M | N | ||
60III | 117 | 147 | 55 | / | 52 | 62 | / | / | ±1 |
80III | 117 | 167 | 55 | / | 52 | 82 | / | / | |
100III | 120 | 190 | 55 | / | 52 | 102 | / | / | |
130III | 125 | 224 | 55 | / | 52 | 132 | / | / |
Cross-reference tables of spec. –parameter | |||||||
Shape | Specification | Rated current ratio (A) | Precision degree and corresponding rated load(VA) | Straight-through tums | Bus spec(mm)/number | Installation | |
0.2 | 0.5 | ||||||
60III | 200-300/5(1) | 2.5 | 60×10/1-3 | E | |||
400/5(1) | 5 | 1 | |||||
500-800/5(1) | 10 | 1 | |||||
1000/5(1) | 10 | 1 | |||||
1200-1500/5(1) | 15 | 1 | |||||
2000/5(1) | 20 | 1 | |||||
2500/5(1) | 30 | 1 | |||||
80III | 300-400/5(1) | 5 | 1 | 80×10/1-3 | |||
500-800/5(1) | 10 | 1 | |||||
1000/5(1) | 10 | 1 | |||||
1200-1500/5(1) | 15 | 1 | |||||
2000/5(1) | 20 | 1 | |||||
2500-3000/5(1) | 30 | 1 | |||||
100III | 600-800/5(1) | 10 | 1 | 100×10/1─3 | |||
1000/5(1) | 10 | 1 | |||||
1200-1500/5(1) | 15 | 1 | |||||
2000/5(1) | 20 | 1 | |||||
2500-5000/5(1) | 30 | 1 | |||||
130III | 2000/5(1) | 20 | 1 | 130×10/1-3 125×10/1-3 | |||
2500-6300/5(1) | 30 | 1 |
AKH-0.66/III Series Current Transformer is installed in E-Type: Fixed by generatrix. Note that when the current transformer is in use, the secondary open circuit shall not be allowed, and the secondary outlet S2 shall be grounded.Rated operation voltage AC 0.66kV and Rated frequency 50-60Hz.Used in place without direct rain and snow,without severe pollution and acute shock.
Clamshell design easy to view wiring
Beautiful shape easy wiring
high accurancy with CE standard
suitable for busbar
Used for internal measurement in industrial and mining enterprises
Measure 1-3 busbar in the power distribution room
Convert the large current at the primary side to 5A or 1A, connect to energy meter
When using a current transformer, the secondary open circuit is not allowed, and the secondary outlet S2 should be grounded
Any IoT energy management system problem pls contact us, our experts will reply you within 24 hours.